What situations can be emergency stopped?
Release time:
2024-01-26
What situations can be emergency stopped?
If the following situations occur, the air compressor should be shut down urgently by pressing the emergency shutdown button, identifying the cause, troubleshooting, and then starting up.
The current and exhaust pressure gauges suddenly exceed the specified values;
2. The cooling water of the water-cooled air compressor suddenly shuts down, causing the supply of cooling to be interrupted:
3. When the water temperature and oil temperature of a certain part of the air compressor exceed the allowable value and the automatic control system malfunctions, emergency shutdown should be carried out:
4. The air compressor emits abnormal sounds, such as metal collision, loose connections, damaged cylinders, cylinder heads, screws, and other components;
5. When the lubricating oil pressure drops or suddenly stops supplying;
6. There are serious leaks and leaks during the gas transportation process of the air compressor;
7. When there is strong vibration or burning odor in the motor;
8. When the weather suddenly becomes abnormal, water enters the air compressor station building, or there is an emergency situation in the surrounding area.
How to emergency stop?
In case of emergency shutdown, there is no need to unload first. You can directly press the "Emergency Stop" button.
After shutdown, the remaining air in the system should be discharged and the pressure should be reset to zero after the air compressor has finished working. After a period of shutdown, the condensate water in the oil and gas drum, oil cooler, and aftercooler should be discharged. If it is cold in winter, it should be avoided to freeze crack, damage, and rust in a low-temperature environment.
Emergency stop record inspection
After an emergency shutdown, it is recommended that you keep a written record of the reason for the shutdown for maintenance and inspection, including:
1. Downtime and type of downtime;
2. Preliminary assessment of emergency shutdown losses;
3. Preliminary Cause Analysis of Emergency Shutdown Accidents
4. Matters requiring assistance from relevant departments for rescue and rescue:
5. Recovery or repair time;
How to reset the emergency stop?
How to reset the air compressor after emergency shutdown?
1. The emergency stop switch has been pressed. Turn the emergency stop switch clockwise to see if it pops up. If not possible, replace the emergency stop switch
2. After the air compressor is idle for a long time, please reset it when starting up, but the reset does not work. In this case, it can be preliminarily judged that the emergency stop switch is disconnected or the emergency stop control circuit has poor contact, and the emergency stop switch can be replaced or repaired.