Do a good job of cleaning the machine, and cold water cleaning is strictly prohibited after the air compressor runs for a long time.
1、Do a good job of cleaning the machine, and cold water cleaning is strictly prohibited after the air compressor runs for a long time.
2、Regularly conduct manual exhaust test on the safety valve of the air storage tank to ensure that the safety valve is normal and effective.
3、Operators should be specially trained and must fully understand the structure, performance and function of the air compressor and auxiliary equipment, and be familiar with the operation and maintenance procedures.
4、Air compressor should be kept away from steam and dust. The air inlet pipe should be equipped with a filtering device.
5、Keep the outside of the air storage tank clean. Welding or thermal processing near the gas storage tank is prohibited. The gas storage tank should be tested annually with hydraulic pressure, and the test pressure should be 1.5 times of the working pressure. Gas pressure gauge and safety valve should be regularly checked and replaced.
6, when cleaning the heat sink, do not use the combustion method to remove the pipe oil. Cleaning and tightening and other maintenance work can be done only after the machine is stopped. It is strictly forbidden to point the air outlet at the human body or other equipment to prevent injury or damage.
7、Operators should wear overalls, and women should tuck their braids into their work caps. It is strictly forbidden to operate after drinking, to leave the work station without permission, and to find someone to replace the work at will.
8、When the air compressor is stopped, gradually open the exhaust valve of the storage tank, slowly reduce the pressure, correspondingly reduce the speed of the diesel engine and make the air compressor run at low speed with no load for 5 to 10 seconds. After stopping, the diesel engine continues to run at low speed for 5 seconds before stopping. In winter, when the temperature is lower than 5 degrees, the cooling water without antifreeze should be drained after stopping.
9. Before starting the air compressor, check and prepare as required, and pay attention to open all valves of the gas storage tank. After the diesel engine is started, it must be run at low speed, medium speed and rated speed for heating. Pay attention to the normal readings of each meter before running with load. The air compressor should be started by gradually increasing the load and only run at full load after all parts are normal.
10、During the operation of the air compressor, pay attention to the meter readings and stop immediately to check if abnormalities are found. The air pressure in the storage tank. The atmospheric pressure should not exceed the pressure specified on the nameplate. Every 2-4 hours of operation, open the condensate oil and water discharge valve of the intercooler and gas storage tank 1 or 2 times.